1 Intelligent Building Weak System Integration (IBM S) Intelligent building was born and developed with the development of the information industry. Its essence is the networking of many intelligent devices and systems in buildings. Taking into account the openness, standardization, versatility and scalability of the system integration software, the large monitoring and management software BS2000 of SIEBE I/A system is used. It can run on MS and operating system, providing visualization, control and real-time. Relational databases, I/O Servers, powerful graphics, direct control from PCs, collecting and analyzing historical data, viewing BAS data, visual objects and various other data resources over the Internet.

The selected integrated management system I/A is an open distribution system with standardized control bus structure, which can be integrated with third-party control systems in different ways according to the characteristics of different weak electronic systems.

Fieldbus level interconnection: I / A series field controllers all adopt Lonworks communication specification. Because its network protocol Lontalk is completely open, it is equal to any user. Any product marked with Lonworks labeling can be implemented at the field bus level with system equipment. Interoperability, including most air conditioner manufacturers, fire manufacturers and security vendors.

Communication gateway interconnection: If the equipment of other subsystems does not meet the above standards, the information exchange with the field bus can be realized through the dedicated programmable control serial communication gateway LON SIF, and communication and linkage with other systems can be realized. At the same time, the system is required to have RS232 or serial communication port, and can provide data such as serial communication instruction set.

Control bus network layer interconnection: I / A series network controller, communication standard uses communication protocol, and has BACnet software communication interface, which can be interconnected with third-party systems in various ways.

Shared real-time database: Data bidirectional dynamic exchange through ODBC, or invoking InSQL Server real-time relational database through SQ L instruction data, thus realizing information sharing between IBM S and other systems.

Software user interface: Data exchange between subsystem application and software user interface is realized by typical data exchange mode under Windows operating system such as DDE, OLE, OPC.

Dedicated drivers: Connect to other subsystems using Wonder Ware's existing more than 200 drivers or using the Tool QIT software toolkit to develop driver-specific drivers (I/O Servers).

BACnet standard interface: The I/A system provides a BACnet standard interface over Ethernet to interconnect with other subsystems using the BACnet communication standard with a defined data format definition.

Data exchange, so that subsystem data can be summarized by writing a dedicated I/O interface program and system data such as Westinghouse access control. Jonson Controls' M ATASYS system can perform data transfer through the DDE data interface of its own monitoring software to achieve data aggregation of each subsystem.

It can also realize linkage between subsystems, such as: linkage between closed-circuit television monitoring system (CCTV) and fire alarm system, linkage between fire alarm system and smart card access control system, linkage between fire alarm system and distribution lighting and ventilation system in building automation system , CCTV and anti-theft alarm system linkage and public information database system connection, maintenance system networking and remote fault diagnosis system networking.

2 Building Automation Control System (BAS) Inner Mongolia Science and Technology Building Automation System (BAS) and Building Management System (BM S) use the same network system, set up a dedicated BAS sub-control station, and the structure of the distributed field controller (DDC) Through the automatic monitoring and effective management of air conditioning systems, water supply and drainage systems, power distribution systems, lighting systems, elevator systems, to achieve good energy and human resources. The system uses actuators manufactured by Honeywell, USA.

3 Office Automation System (OAS) office automation system is a computer-based, modern office environment with comprehensive information processing capabilities, using computer multimedia technology to provide text, sound, image as one of the graphic office tools. It mainly consists of decision support system, personal transaction processing system, office transaction processing system, public information processing system, property management system, multi-function conference system and LED large screen system.

The audio and sound reinforcement system uses two TICO ES amplifiers and two pairs of speakers, and is equipped with a BOSE 802C controller for frequency division and voltage limit protection. The installation of the speakers should be coordinated with the interior decoration. The mixer selects the LIV E product of SO UN DCRAFT, and at the same time, it adjusts the spectrum curve in the hall at any time, suppresses the acoustic feedback, and selects the feedback suppressor.

The video system uses EPSON EM P9000 projector, which has a large-screen projection effect, and can access various audio and video signals and computer signals, especially suitable for the venue demonstration environment. In order to realize signal conversion and real-time monitoring of the venue, EX TRON's audio and video multi-way switch and selector switch are selected. The executive chairman of the conference can monitor each input signal source at any time by AMX automatic control system to realize information sharing.

4 Communication automation system (CAS) takes into account and has been developed and utilized. The communication automation system of this design is designed with ISDN, B ISDN, port and urban public telephone data network using optical cable connection, and can also be realized by ATM and B ISDN. High speed data and high definition image transmission. 500 channels of outgoing, incoming trunks and dedicated lines are set up, and private lines are connected to public networks, including packet switching networks and digital switching networks. A 2.4 GHz, 8 GHz microwave station is installed to enable remote communication and image transmission within the system, and a satellite television receiving station for receiving satellite programs.

The subsystem includes a computer network system, an all-digital program-controlled switch system, a microwave communication system, a trunking communication system, and a conference television system. The backbone network uses the 625M ATM high-speed backbone network as the main information circulation trunk road, and uses the optical cable as the transmission medium to realize the networking of the entire building resources. The backbone network is also the company O AS network, which adopts the US CISCO company products. The department subnet adopts 625M A TM , 1000M or 100M switching Ethernet, and the subnet is distributed to the switching network, production scheduling automation network, financial subnet, BAS subnet, etc. The backbone network communicates with the external network through fiber optic cable or microwave, and the module directly accesses the computer network to enable the computer network in the building to exchange information with the remote network and the remote computer through PBAX. The program-controlled switch has a capacity of 2000 doors, and the number of incoming and outgoing trunks and dedicated lines is 500. The system's interrupted network access mode uses the full 5 structured integrated wiring system (PDS). The structured wiring system is the optimal wiring method for the weak current system. It can fully support each. The advanced and reliable information highway of intelligent system information transmission realizes flexible and convenient fast transmission of voice, high and low speed data. The structured cabling system includes six subsystems: building group subsystem, equipment management subsystem, vertical trunk subsystem, management subsystem, horizontal trunk subsystem and work area subsystem. The computer network cable, telecommunication communication line, BAS data line and A complete wiring system is unified on the same axis to meet future expansion.

6 Integrated Security System (S AS) integrated security system includes closed-circuit surveillance TV and anti-theft alarm and monitoring system, entrance and exit monitoring management system, parking management system and patrol management system. An independent security management workstation is set up, which adopts an independent network structure system and multiple layers of distributed systems that can be operated independently, so that any device in the system fails without affecting the normal operation of the entire system. The security management workstation and the BM S monitoring management workstation are in a parallel processing distributed computer network system, making the two workstations a unified monitoring workstation.